Home / Sensors / JXBS-3001-NPK-RS

JXCT · RS-485 sensor

Weihai JXCT Electronics

JXBS-3001-NPK-RS

JXCT standalone N-P-K probe (3 registers from 0x001E).

✓ Verified for SankhyaN-P-KVerification 0.95 · datasheet-confirmed
At a glance

The JXBS-3001-NPK-RS is a single-parameter RS-485 soil probe reporting N-P-K over Modbus-RTU on RS-485 at 9600 bps, 8N1, on DC 12–24 V. This guide documents 5 registers, default Modbus address 1. It does not report moisture, temperature, EC and others. For those on the same bus: moisture → JXBS-3001-TR (4-in-1); temperature → JXBS-3001-TR (4-in-1). Sankhya firmware profile: JXCT_NPK_only.

Bus & electrical specs

Protocol
Modbus-RTU over RS-485
Default baud
9600 bps
Serial format
8N1
Function codes
0x03
Supply voltage
DC 12–24 V
Power
≤ 0.15 W (12 V DC)
Default address
1
Ingress / housing
IP68
Probe / element
316L stainless steel
Operating temp.
−40 to +80 °C (probe)
Firmware profile
JXCT_NPK_only

Specs sourced from: Official JXBS-3001-TR datasheet (R208894) and JXCT manuals.

Modbus-RTU register map

Function codes 0x03 at 9600 bps, 8N1. Data registers are read with 0x03; configuration registers are written with 0x06. PLC column shows the 4xxxx Modbus holding-register convention.

RegisterPLCParameterTypeScaleUnitR/WNotes
001EH40031Nitrogenuint161mg/kgRO
001FH40032Phosphorusuint161mg/kgRO
0020H40033Potassiumuint161mg/kgRO
0100H40257Device addressuint161RW
0101H40258Baud rateuint161RW2400=2400; 4800=4800; 9600=9600

Worked query

Changing address & baud rate

This probe is configured over the same RS-485 bus using Modbus write commands (function code 0x06). Configure one device at a time on the bus.

Notes & caveats

NPK-only variant. Live probe readings confirmed from uploaded manual. Default baud 9600.

Common questions

What baud rate does the JXBS-3001-NPK-RS use by default?
9600 bps, 8N1. It is a Modbus-RTU slave; default address 1.
What supply voltage does the JXBS-3001-NPK-RS need?
DC 12–24 V (≤ 0.15 W (12 V DC)).
How do I change the JXBS-3001-NPK-RS Modbus address?
Write the device-address register with function code 0x06, one device on the bus at a time, then power-cycle. See the Configuration section above.
Is the JXBS-3001-NPK-RS compatible with the Sankhya platform?
Yes — it is in the Sankhya RS-485 sensor library and the firmware-generation pipeline can produce node firmware for it.
What does the JXBS-3001-NPK-RS not measure?
The JXBS-3001-NPK-RS reports N-P-K only — it does not report moisture, temperature, EC, pH, salinity and TDS. On the same RS-485 bus, add moisture: JXBS-3001-TR (4-in-1); temperature: JXBS-3001-TR (4-in-1); EC: JXBS-3001-TR (4-in-1).
How many Modbus registers does the JXBS-3001-NPK-RS expose?
This guide documents 5 registers, read with function code 0x03 and written with 0x06 where the register is RW. Documented entries include Nitrogen, Phosphorus, Potassium, Device address and Baud rate.

How this differs from similar models

How the JXBS-3001-NPK-RS compares with the other RS-485 models in the Sankhya library. "Drop-in" means the same parameter set and the same register map, read by the same firmware profile.

ModelRelationshipMeasuresBaudDifference
JXBS-3001-TR (7-in-1)SiblingMoisture, Temperature, EC, pH, N-P-K9600Adds moisture, temperature, EC and pH.
JXBS-3001-PH-RSSiblingpH9600Adds pH, drops N-P-K.
JXBS-3001-TR (4-in-1)SiblingMoisture, Temperature, EC, pH9600Adds moisture, temperature, EC and pH, drops N-P-K.

Related JXCT sensors

Run this sensor on a Sankhya node

Every sensor on this page is in our RS-485 library. Pick your model, and the firmware-generation pipeline builds the Modbus (or ASCII) polling code for an ESP32-S3 node — no hand-coding the register math.