Home / Sensors / Renke RS-ECTHPH-N01-TR-1

Renke · RS-485 sensor

Shandong Renke Control Technology

Renke RS-ECTHPH-N01-TR-1

Renke 4-in-1 — moisture, temp, EC, pH (ZTS-compatible registers).

✓ Verified for SankhyaMoistureTemperatureECpHSalinityTDSVerification 0.95 · datasheet-confirmed
At a glance

The Renke RS-ECTHPH-N01-TR-1 is a 6-in-1 RS-485 soil probe reporting moisture, temperature, EC, pH, salinity and TDS over Modbus-RTU on RS-485 at 4800 bps, 8N1, on DC 4.5–30 V. This guide documents 15 registers, default Modbus address 1. It does not report N-P-K. For those on the same bus: N-P-K → JXBS-3001-TR (7-in-1). It is register-compatible with the SN-3001-TR-ECTHPH-N01 and ZTS-3001-TR-ECTHPH-N01, which the same firmware profile reads unchanged. Sankhya firmware profile: ZTS_4in1_ECTHPH.

Bus & electrical specs

Protocol
Modbus-RTU over RS-485
Default baud
4800 bps
Serial format
8N1
Function codes
0x03, 0x06
Supply voltage
DC 4.5–30 V
Power
≤ 0.5 W (24 V DC)
Default address
1
Ingress / housing
IP68
Probe / element
Corrosion-resistant electrode (stainless)
Operating temp.
−20 to +60 °C
Dimensions
45 × 15 × 127 mm
Cable
2 m (default, customisable)
Response time
≤ 1 s
Stabilisation
≤ 5 min
Firmware profile
ZTS_4in1_ECTHPH

Specs sourced from: Official Renke RS-ECTHPH-N01-TR-1 product page & manual.

Modbus-RTU register map

Function codes 0x03, 0x06 at 4800 bps, 8N1. Data registers are read with 0x03; configuration registers are written with 0x06. PLC column shows the 4xxxx Modbus holding-register convention.

RegisterPLCParameterTypeScaleUnitR/WNotes
0000H40001Soil moistureuint160.1%RO
0001H40002Soil temperatureint160.1°CRO
0002H40003Electrical conductivityuint161uS/cmRO
0003H40004pHuint160.1pHRO
0004H40005Salinityuint161mg/LRO
0005H40006TDSuint161mg/LRO
0022H40035EC temperature coefficientuint160.1%/°CRW
0023H40036Salinity coefficientuint160.01RW
0024H40037TDS factoruint160.01RW
0050H40081Temperature calibrationint160.1°CRW
0051H40082Moisture calibrationint160.1%RW
0052H40083EC calibrationint161uS/cmRW
0053H40084pH calibrationint161RW
07D0H42001Device addressuint161RW
07D1H42002Baud rateuint161RW

Worked query

Changing address & baud rate

This probe is configured over the same RS-485 bus using Modbus write commands (function code 0x06). Configure one device at a time on the bus.

Ranges & accuracy

ParameterRangeAccuracy
Soil moisture0–100 %RH±2 % (0–50 %RH), ±3 % (50–100 %RH)
Soil temperature−40 to +80 °C±0.5 °C @ 25 °C
EC0–20000 µS/cm±3 %FS (0–10000), ±5 %FS (10000–20000)
pH3–9 pH±0.3 pH

Notes & caveats

Upgraded to 0.95 — official Renke RS-ECTHPH-N01-TR-1 manual V1.2 (renkeer.com) uploaded and verified. Register map confirmed: 0000H=moisture×0.1%, 0001H=temp×0.1°C, 0002H=EC(us/cm), 0003H=pH×0.1, 0004H=salinity, 0005H=TDS. Communication example in manual: query 01 03 00 00 00 04 44 09, response 01 03 08 [moisture][temp][EC][pH] CRC. Added salinity, TDS, coefficient (0022H-0024H) and calibration (0050H-0053H) registers from official manual. Register layout fully confirmed identical to ZTS_4in1_ECTHPH family. Default baud 4800 confirmed.

Common questions

What baud rate does the Renke RS-ECTHPH-N01-TR-1 use by default?
4800 bps, 8N1. It is a Modbus-RTU slave; default address 1.
What supply voltage does the Renke RS-ECTHPH-N01-TR-1 need?
DC 4.5–30 V (≤ 0.5 W (24 V DC)).
How do I change the Renke RS-ECTHPH-N01-TR-1 Modbus address?
Write the device-address register with function code 0x06, one device on the bus at a time, then power-cycle. See the Configuration section above.
Is the Renke RS-ECTHPH-N01-TR-1 compatible with the Sankhya platform?
Yes — it is in the Sankhya RS-485 sensor library and the firmware-generation pipeline can produce node firmware for it.
Does the Renke RS-ECTHPH-N01-TR-1 measure N-P-K?
The Renke RS-ECTHPH-N01-TR-1 reports moisture, temperature, EC, pH, salinity and TDS only — it does not report N-P-K. On the same RS-485 bus, add N-P-K: JXBS-3001-TR (7-in-1).
Is the Renke RS-ECTHPH-N01-TR-1 the same as the SN-3001-TR-ECTHPH-N01?
They are register-compatible, not identical products. Both expose the same parameter set and the same Modbus register map, and Sankhya reads both with the ZTS_4in1_ECTHPH firmware profile. Housing, cable gland and probe material can differ between vendors, so check the electrical specs above before substituting one for the other.

How this differs from similar models

How the Renke RS-ECTHPH-N01-TR-1 compares with the other RS-485 models in the Sankhya library. "Drop-in" means the same parameter set and the same register map, read by the same firmware profile.

ModelRelationshipMeasuresBaudDifference
SN-3001-TR-ECTHPH-N01Drop-inMoisture, Temperature, EC, pH, Salinity, TDS4800Same parameter set and register map. No documented differences.
ZTS-3001-TR-ECTHPH-N01Drop-inMoisture, Temperature, EC, pH, Salinity, TDS4800Same parameter set and register map. Differs in supply range (DC 5–30 V).
Renke RS-WS-N01-TRSiblingMoisture, Temperature4800Drops EC, pH, salinity and TDS.
Renke RS-SD-N01-TR-1SiblingMoisture9600Drops temperature, EC, pH, salinity and TDS. Default baud 9600.

Related Renke sensors

Run this sensor on a Sankhya node

Every sensor on this page is in our RS-485 library. Pick your model, and the firmware-generation pipeline builds the Modbus (or ASCII) polling code for an ESP32-S3 node — no hand-coding the register math.

Contact Us