Home / Sensors / SN-3001-TR-ECTHPH-N01

SN · RS-485 sensor

Puruisenshe (普锐森社)

SN-3001-TR-ECTHPH-N01

4-in-1 probe (ZTS-compatible) — moisture, temp, EC, pH.

✓ Verified for SankhyaMoistureTemperatureECpHSalinityTDSVerification 0.95 · datasheet-confirmed
At a glance

The SN-3001-TR-ECTHPH-N01 is a 6-in-1 RS-485 soil probe reporting moisture, temperature, EC, pH, salinity and TDS over Modbus-RTU on RS-485 at 4800 bps, 8N1, on DC 4.5–30 V. This guide documents 15 registers, default Modbus address 1. It does not report N-P-K. For those on the same bus: N-P-K → SN-3002-TR-ECTHNPKPH-N01. It is register-compatible with the Renke RS-ECTHPH-N01-TR-1 and ZTS-3001-TR-ECTHPH-N01, which the same firmware profile reads unchanged. Sankhya firmware profile: ZTS_4in1_ECTHPH.

Bus & electrical specs

Protocol
Modbus-RTU over RS-485
Default baud
4800 bps
Serial format
8N1
Function codes
0x03, 0x06
Supply voltage
DC 4.5–30 V
Power
≤ 0.5 W (24 V DC)
Default address
1
Ingress / housing
IP68
Probe / element
Stainless steel
Operating temp.
−40 to +80 °C (probe)
Firmware profile
ZTS_4in1_ECTHPH

Specs sourced from: Official SN-3001-TR-*-N01 datasheet (R224096); ZTS-compatible register layout.

Modbus-RTU register map

Function codes 0x03, 0x06 at 4800 bps, 8N1. Data registers are read with 0x03; configuration registers are written with 0x06. PLC column shows the 4xxxx Modbus holding-register convention.

RegisterPLCParameterTypeScaleUnitR/WNotes
0000H40001Soil moistureuint160.1%RO
0001H40002Soil temperatureint160.1°CRONegative values in two's complement.
0002H40003Electrical conductivityuint161uS/cmRO
0003H40004pHuint160.1pHRO
0007H40008Salinityuint161mg/LROReference value only.
0008H40009TDSuint161mg/LROReference value only.
0022H40035Conductivity temperature coefficientuint160.1%RWDefault 0 (0.0%).
0023H40036Salinity conversion coefficientuint160.01RWDefault 55 (0.55).
0024H40037TDS conversion coefficientuint160.01RWDefault 50 (0.50).
0050H40081Temperature calibration valueint160.1°CRW
0051H40082Moisture calibration valueint160.1%RW
0052H40083Conductivity calibration valueint161uS/cmRW
0053H40084pH calibration valueint160.1pHRW
07D0H42001Device addressuint161RWRange 1-254. Factory default 1.
07D1H42002Baud rateuint161RWFactory default 1 (4800 bps). 0=2400; 1=4800; 2=9600

Worked query

# Read moisture+temp+EC+pH (4 registers from 0x0000) request 01 03 00 00 00 04 44 09 response 01 03 08 02 92 FF 9B 03 E8 00 38 57 B6 # moisture=65.8%, temperature=-10.1°C, EC=1000 uS/cm, pH=5.6

Changing address & baud rate

This probe is configured over the same RS-485 bus using Modbus write commands (function code 0x06). Configure one device at a time on the bus.

Notes & caveats

Different manufacturer (Puruisenshe) but IDENTICAL register map to ZTS family. Confirmed from uploaded official datasheet. Share firmware profile ZTS_4in1_ECTHPH.

Common questions

What baud rate does the SN-3001-TR-ECTHPH-N01 use by default?
4800 bps, 8N1. It is a Modbus-RTU slave; default address 1.
What supply voltage does the SN-3001-TR-ECTHPH-N01 need?
DC 4.5–30 V (≤ 0.5 W (24 V DC)).
How do I change the SN-3001-TR-ECTHPH-N01 Modbus address?
Write the device-address register with function code 0x06, one device on the bus at a time, then power-cycle. See the Configuration section above.
Is the SN-3001-TR-ECTHPH-N01 compatible with the Sankhya platform?
Yes — it is in the Sankhya RS-485 sensor library and the firmware-generation pipeline can produce node firmware for it.
Does the SN-3001-TR-ECTHPH-N01 measure N-P-K?
The SN-3001-TR-ECTHPH-N01 reports moisture, temperature, EC, pH, salinity and TDS only — it does not report N-P-K. On the same RS-485 bus, add N-P-K: SN-3002-TR-ECTHNPKPH-N01.
Is the SN-3001-TR-ECTHPH-N01 the same as the Renke RS-ECTHPH-N01-TR-1?
They are register-compatible, not identical products. Both expose the same parameter set and the same Modbus register map, and Sankhya reads both with the ZTS_4in1_ECTHPH firmware profile. Housing, cable gland and probe material can differ between vendors, so check the electrical specs above before substituting one for the other.

How this differs from similar models

How the SN-3001-TR-ECTHPH-N01 compares with the other RS-485 models in the Sankhya library. "Drop-in" means the same parameter set and the same register map, read by the same firmware profile.

ModelRelationshipMeasuresBaudDifference
Renke RS-ECTHPH-N01-TR-1Drop-inMoisture, Temperature, EC, pH, Salinity, TDS4800Same parameter set and register map. No documented differences.
ZTS-3001-TR-ECTHPH-N01Drop-inMoisture, Temperature, EC, pH, Salinity, TDS4800Same parameter set and register map. Differs in supply range (DC 5–30 V).
SN-3002-TR-ECTHNPKPH-N01SiblingMoisture, Temperature, EC, pH, N-P-K, Salinity, TDS4800Adds N-P-K.

Related SN sensors

Run this sensor on a Sankhya node

Every sensor on this page is in our RS-485 library. Pick your model, and the firmware-generation pipeline builds the Modbus (or ASCII) polling code for an ESP32-S3 node — no hand-coding the register math.

Contact Us